Updated as of: 2025-11-19 - Network architecture corrections applied
Network Architecture (UPDATED)
Cluster Management Network:10.11.11.0/24 (vmbr0)
Primary cluster communication and SSH access
n2: 10.11.11.12
n3: 10.11.11.13
n4: 10.11.11.14
VM Network and Backup Cluster Network:10.1.1.0/24 (vmbr1)
VM traffic and backup cluster communication
n2: 10.1.1.12
n3: 10.1.1.13
n4: 10.1.1.14
TB4 Mesh Network:10.100.0.0/24 (en05/en06)
High-speed TB4 interfaces for Ceph cluster_network
Isolated from client I/O traffic
Provides optimal performance for Ceph OSD communication
SSH Key Setup (UPDATED)
Critical: Before proceeding with any configuration, you must set up SSH key authentication for passwordless access to all nodes.
Step 1: Generate SSH Key (if you don't have one)
# Generate a new SSH key (if needed):
ssh-keygen -t ed25519 -C "cluster-ssh-key" -f ~/.ssh/cluster_key
Step 2: Accept Host Keys (First Time Only)
IMPORTANT: Before running the deployment commands, you must SSH into each node once to accept the host key:
# Accept host keys for all nodes (type 'yes' when prompted):
ssh root@10.11.11.12 "echo 'Host key accepted for n2'"
ssh root@10.11.11.13 "echo 'Host key accepted for n3'"
ssh root@10.11.11.14 "echo 'Host key accepted for n4'"
Note: This step is required because the first SSH connection to each host requires accepting the host key. Without this, the automated deployment commands will fail.
Step 3: Deploy SSH Key to All Nodes
Deploy your public key to each node's authorized_keys:
# Test passwordless SSH access to all nodes:fornodein 10.11.11.12 10.11.11.13 10.11.11.14;doecho"Testing SSH access to $node..."
ssh root@$node"echo 'SSH key authentication working on $node'"done
Expected result: All nodes should respond without prompting for a password.
TB4 Hardware Detection (UPDATED)
Step 1: Prepare All Nodes
Critical: Perform these steps on ALL mesh nodes (n2, n3, n4).
# Create en05 bringup script for all nodes:fornodein n2 n3 n4;do
ssh $node"cat > /usr/local/bin/pve-en05.sh << 'EOF'#!/bin/bashLOGFILE=\"/tmp/udev-debug.log\"echo \"\$(date): en05 bringup triggered\" >> \"\$LOGFILE\"for i in {1..5}; do { ip link set en05 up mtu 65520 echo \"\$(date): en05 up successful on attempt \$i\" >> \"\$LOGFILE\" break } || { echo \"\$(date): Attempt \$i failed, retrying in 3 seconds...\" >> \"\$LOGFILE\" sleep 3 }doneEOF"
ssh $node"chmod +x /usr/local/bin/pve-en05.sh"done# Create en06 bringup script for all nodes:fornodein n2 n3 n4;do
ssh $node"cat > /usr/local/bin/pve-en06.sh << 'EOF'#!/bin/bashLOGFILE=\"/tmp/udev-debug.log\"echo \"\$(date): en06 bringup triggered\" >> \"\$LOGFILE\"for i in {1..5}; do { ip link set en06 up mtu 65520 echo \"\$(date): en06 up successful on attempt \$i\" >> \"\$LOGFILE\" break } || { echo \"\$(date): Attempt \$i failed, retrying in 3 seconds...\" >> \"\$LOGFILE\" sleep 3 }doneEOF"
ssh $node"chmod +x /usr/local/bin/pve-en06.sh"done
Step 7: Update Initramfs and Reboot
Apply all TB4 configuration changes:
# Update initramfs on all nodes:fornodein n2 n3 n4;do
ssh $node"update-initramfs -u -k all"done# Reboot all nodes to apply changes:echo"Rebooting all nodes - wait for them to come back online..."fornodein n2 n3 n4;do
ssh $node"reboot"done# Wait and verify after reboot:echo"Waiting 60 seconds for nodes to reboot..."
sleep 60
# Verify TB4 interfaces after reboot:fornodein n2 n3 n4;doecho"=== TB4 interfaces on $node after reboot ==="
ssh $node"ip link show | grep -E '(en05|en06)'"done
Expected result: TB4 interfaces should be named en05 and en06 with proper MTU settings.
Step 8: Enable IPv4 Forwarding
Essential: TB4 mesh requires IPv4 forwarding for OpenFabric routing.
# Configure IPv4 forwarding on all nodes:fornodein n2 n3 n4;do
ssh $node"echo 'net.ipv4.ip_forward=1' >> /etc/sysctl.conf"
ssh $node"sysctl -p"done
fornodein n2 n3 n4;do
ssh $node"cat > /usr/local/bin/thunderbolt-startup.sh << 'EOF'#!/bin/bash# Thunderbolt interface startup scriptLOGFILE=\"/var/log/thunderbolt-startup.log\"echo \"\$(date): Starting Thunderbolt interface configuration\" >> \"\$LOGFILE\"# Wait up to 30 seconds for interfaces to appearfor i in {1..30}; do if ip link show en05 &>/dev/null && ip link show en06 &>/dev/null; then echo \"\$(date): Thunderbolt interfaces found\" >> \"\$LOGFILE\" break fi echo \"\$(date): Waiting for Thunderbolt interfaces... (\$i/30)\" >> \"\$LOGFILE\" sleep 1done# Configure interfaces if they existif ip link show en05 &>/dev/null; then /usr/local/bin/pve-en05.sh echo \"\$(date): en05 configured\" >> \"\$LOGFILE\"fiif ip link show en06 &>/dev/null; then /usr/local/bin/pve-en06.sh echo \"\$(date): en06 configured\" >> \"\$LOGFILE\"fiecho \"\$(date): Thunderbolt configuration completed\" >> \"\$LOGFILE\"EOF"
ssh $node"chmod +x /usr/local/bin/thunderbolt-startup.sh"done
Note: This service ensures TB4 interfaces come up even if udev rules fail to trigger on boot.
Phase 2: Proxmox SDN Configuration
Step 4: Create OpenFabric Fabric in GUI
Location: Datacenter → SDN → Fabrics
Click: "Add Fabric" → "OpenFabric"
Configure in the dialog:
Name:tb4
IPv4 Prefix:10.100.0.0/24
IPv6 Prefix: (leave empty for IPv4-only)
Hello Interval:3 (default)
CSNP Interval:10 (default)
Click: "OK"
Expected result: You should see a fabric named tb4 with Protocol OpenFabric and IPv4 10.100.0.0/24
Step 5: Add Nodes to Fabric
Still in: Datacenter → SDN → Fabrics → (select tb4 fabric)
Click: "Add Node"
Configure for n2:
Node:n2
IPv4:10.100.0.12
IPv6: (leave empty)
Interfaces: Select en05 and en06 from the interface list
Click: "OK"
Repeat for n3: IPv4: 10.100.0.13, interfaces: en05, en06
Repeat for n4: IPv4: 10.100.0.14, interfaces: en05, en06
Expected result: You should see all 3 nodes listed under the fabric with their IPv4 addresses and interfaces (en05, en06 for each)
Important: You need to manually configure /30 point-to-point addresses on the en05 and en06 interfaces to create mesh connectivity. Example addressing scheme:
n2: en05: 10.100.0.1/30, en06: 10.100.0.5/30
n3: en05: 10.100.0.9/30, en06: 10.100.0.13/30
n4: en05: 10.100.0.17/30, en06: 10.100.0.21/30
These /30 subnets allow each interface to connect to exactly one other interface in the mesh topology. Configure these addresses in the Proxmox network interface settings for each node.
Step 6: Apply SDN Configuration
Critical: This activates the mesh - nothing works until you apply!
In GUI: Datacenter → SDN → "Apply" (button in top toolbar)
Expected result: Status table shows all nodes with "OK" status like this:
SDN Node Status
localnet... n3 OK
localnet... n1 OK
localnet... n4 OK
localnet... n2 OK
Step 7: Start FRR Service
Critical: OpenFabric routing requires FRR (Free Range Routing) to be running.
# Start and enable FRR on all mesh nodes:fornodein n2 n3 n4;do
ssh $node"systemctl start frr && systemctl enable frr"done
Verify FRR is running:
fornodein n2 n3 n4;doecho"=== FRR status on $node ==="
ssh $node"systemctl status frr | grep Active"done
Expected output:
=== FRR status on n2 ===
Active: active (running) since Mon 2025-01-27 20:15:23 EST; 2h ago
=== FRR status on n3 ===
Active: active (running) since Mon 2025-01-27 20:15:25 EST; 2h ago
=== FRR status on n4 ===
Active: active (running) since Mon 2025-01-27 20:15:27 EST; 2h ago
Command-line verification:
# Check SDN services on all nodes:fornodein n2 n3 n4;doecho"=== SDN status on $node ==="
ssh $node"systemctl status frr | grep Active"done
Expected output:
=== SDN status on n2 ===
Active: active (running) since Mon 2025-01-27 20:15:23 EST; 2h ago
=== SDN status on n3 ===
Active: active (running) since Mon 2025-01-27 20:15:25 EST; 2h ago
=== SDN status on n4 ===
Active: active (running) since Mon 2025-01-27 20:15:27 EST; 2h ago
Phase 3: Mesh Verification and Testing
Step 8: Verify Interface Configuration
Check TB4 interfaces are up with correct settings:
fornodein n2 n3 n4;doecho"=== TB4 interfaces on $node ==="
ssh $node"ip addr show | grep -E '(en05|en06|10\.100\.0\.)'"done
Expected output example (n2):
=== TB4 interfaces on n2 ===
inet 10.100.0.12/32 scope global dummy_tb4
11: en05: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 65520 qdisc fq_codel state UP group default qlen 1000
inet 10.100.0.1/30 scope global en05
12: en06: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 65520 qdisc fq_codel state UP group default qlen 1000
inet 10.100.0.5/30 scope global en06
What this shows:
Router ID address:10.100.0.12/32 on dummy_tb4 interface
TB4 interfaces UP:en05 and en06 with state UP
Jumbo frames:mtu 65520 on both interfaces
Point-to-point addresses:/30 subnets for mesh connectivity
Step 9: Test OpenFabric Mesh Connectivity
Critical test: Verify full mesh communication works.
# Test router ID connectivity (should be sub-millisecond):fortargetin 10.100.0.12 10.100.0.13 10.100.0.14;doecho"=== Testing connectivity to $target ==="
ping -c 3 $targetdone
Expected output:
=== Testing connectivity to 10.100.0.12 ===
PING 10.100.0.12 (10.100.0.12) 56(84) bytes of data.
64 bytes from 10.100.0.12: icmp_seq=1 ttl=64 time=0.618 ms
64 bytes from 10.100.0.12: icmp_seq=2 ttl=64 time=0.582 ms
64 bytes from 10.100.0.12: icmp_seq=3 ttl=64 time=0.595 ms
--- 10.100.0.12 ping statistics ---
3 packets transmitted, 3 received, 0% packet loss, time 2003ms
=== Testing connectivity to 10.100.0.13 ===
PING 10.100.0.13 (10.100.0.13) 56(84) bytes of data.
64 bytes from 10.100.0.13: icmp_seq=1 ttl=64 time=0.634 ms
64 bytes from 10.100.0.13: icmp_seq=2 ttl=64 time=0.611 ms
64 bytes from 10.100.0.13: icmp_seq=3 ttl=64 time=0.598 ms
--- 10.100.0.13 ping statistics ---
3 packets transmitted, 3 received, 0% packet loss, time 2004ms
What to look for:
All pings succeed:3 received, 0% packet loss
Sub-millisecond latency:time=0.6xx ms (typical ~0.6ms)
No timeouts or errors: Should see response for every packet
If connectivity fails: TB4 interfaces may need manual bring-up after reboot:
# Bring up TB4 interfaces manually:fornodein n2 n3 n4;do
ssh $node"ip link set en05 up mtu 65520"
ssh $node"ip link set en06 up mtu 65520"
ssh $node"ifreload -a"done
Creating OSD on /dev/nvme0n1
OSD.0 created successfully.
OSD daemon started.
GUI Approach:
Location: Each node → Ceph → OSD → "Create: OSD"
Select: Choose /dev/nvme0n1 and /dev/nvme1n1 from device list
Advanced: Leave DB/WAL settings as default (co-located)
Result: Green "OSD created successfully" messages
Verify all OSDs are up:
ssh n2 "ceph osd tree"
Expected output:
ID CLASS WEIGHT TYPE NAME STATUS REWEIGHT PRI-AFF
-1 5.45776 root default
-3 1.81959 host n2
0 ssd 0.90979 osd.0 up 1.00000 1.00000
1 ssd 0.90979 osd.1 up 1.00000 1.00000
-5 1.81959 host n3
2 ssd 0.90979 osd.2 up 1.00000 1.00000
3 ssd 0.90979 osd.3 up 1.00000 1.00000
-7 1.81959 host n4
4 ssd 0.90979 osd.4 up 1.00000 1.00000
5 ssd 0.90979 osd.5 up 1.00000 1.00000
What to verify:
6 OSDs total: 2 per mesh node (osd.0-5)
All 'up' status: Every OSD shows up in STATUS column
Weight 1.00000: All OSDs have full weight (not being rebalanced out)
Hosts organized: Each node (n2, n3, n4) shows as separate host with 2 OSDs
Phase 5: High-Performance Optimizations
Step 17: Memory Optimizations (64GB RAM Nodes)
Configure optimal memory usage for high-performance hardware:
# Set OSD memory target to 8GB per OSD (ideal for 64GB nodes):
ssh n2 "ceph config set osd osd_memory_target 8589934592"# Set BlueStore cache sizes for NVMe performance:
ssh n2 "ceph config set osd bluestore_cache_size_ssd 4294967296"# Set memory allocation optimizations:
ssh n2 "ceph config set osd osd_memory_cache_min 1073741824"
ssh n2 "ceph config set osd osd_memory_cache_resize_interval 1"
Step 18: CPU and Threading Optimizations (13th Gen Intel)
Optimize for high-performance CPUs:
# Set CPU threading optimizations:
ssh n2 "ceph config set osd osd_op_num_threads_per_shard 2"
ssh n2 "ceph config set osd osd_op_num_shards 8"# Set BlueStore threading for NVMe:
ssh n2 "ceph config set osd bluestore_sync_submit_transaction false"
ssh n2 "ceph config set osd bluestore_throttle_bytes 268435456"
ssh n2 "ceph config set osd bluestore_throttle_deferred_bytes 134217728"# Set CPU-specific optimizations:
ssh n2 "ceph config set osd osd_client_message_cap 1000"
ssh n2 "ceph config set osd osd_client_message_size_cap 1073741824"
Step 19: Network Optimizations for TB4 Mesh
Optimize network settings for TB4 high-performance cluster communication:
# Set network optimizations for TB4 mesh (65520 MTU, sub-ms latency):
ssh n2 "ceph config set global ms_tcp_nodelay true"
ssh n2 "ceph config set global ms_tcp_rcvbuf 134217728"
ssh n2 "ceph config set global ms_tcp_prefetch_max_size 65536"# Set cluster network optimizations for 10.100.0.0/24 TB4 mesh:
ssh n2 "ceph config set global ms_cluster_mode crc"
ssh n2 "ceph config set global ms_async_op_threads 8"
ssh n2 "ceph config set global ms_dispatch_throttle_bytes 1073741824"# Set heartbeat optimizations for fast TB4 network:
ssh n2 "ceph config set osd osd_heartbeat_interval 6"
ssh n2 "ceph config set osd osd_heartbeat_grace 20"
Step 20: BlueStore and NVMe Optimizations
Configure BlueStore for maximum NVMe and TB4 performance:
# Set BlueStore optimizations for NVMe drives:
ssh n2 "ceph config set osd bluestore_compression_algorithm lz4"
ssh n2 "ceph config set osd bluestore_compression_mode aggressive"
ssh n2 "ceph config set osd bluestore_compression_required_ratio 0.7"# Set NVMe-specific optimizations:
ssh n2 "ceph config set osd bluestore_cache_trim_interval 200"# Set WAL and DB optimizations for NVMe:
ssh n2 "ceph config set osd bluestore_block_db_size 5368709120"
ssh n2 "ceph config set osd bluestore_block_wal_size 1073741824"
Step 21: Scrubbing and Maintenance Optimizations
Configure scrubbing for high-performance environment:
# Set scrubbing optimizations:
ssh n2 "ceph config set osd osd_scrub_during_recovery false"
ssh n2 "ceph config set osd osd_scrub_begin_hour 2"
ssh n2 "ceph config set osd osd_scrub_end_hour 6"# Set deep scrub optimizations:
ssh n2 "ceph config set osd osd_deep_scrub_interval 1209600"
ssh n2 "ceph config set osd osd_scrub_max_interval 1209600"
ssh n2 "ceph config set osd osd_scrub_min_interval 86400"# Set recovery optimizations for TB4 mesh:
ssh n2 "ceph config set osd osd_recovery_max_active 8"
ssh n2 "ceph config set osd osd_max_backfills 4"
ssh n2 "ceph config set osd osd_recovery_op_priority 1"
Phase 6: Storage Pool Creation and Configuration
Step 22: Create High-Performance Storage Pool
Create optimized storage pool with 2:1 replication ratio:
# Create pool with optimal PG count for 6 OSDs (256 PGs = ~85 PGs per OSD):
ssh n2 "ceph osd pool create cephtb4 256 256"# Set 2:1 replication ratio (size=2, min_size=1) for test lab:
ssh n2 "ceph osd pool set cephtb4 size 2"
ssh n2 "ceph osd pool set cephtb4 min_size 1"# Enable RBD application for Proxmox integration:
ssh n2 "ceph osd pool application enable cephtb4 rbd"
Step 23: Verify Cluster Health
Check that cluster is healthy and ready:
ssh n2 "ceph -s"
Expected results:
Health: HEALTH_OK (or HEALTH_WARN with minor warnings)
OSDs: 6 osds: 6 up, 6 in
PGs: All PGs active+clean
Pools: cephtb4 pool created and ready
Phase 7: Performance Testing and Validation
Step 24: Test Optimized Cluster Performance
Run comprehensive performance testing to validate optimizations:
# Test write performance with optimized cluster:
ssh n2 "rados -p cephtb4 bench 10 write --no-cleanup -b 4M -t 16"# Test read performance:
ssh n2 "rados -p cephtb4 bench 10 rand -t 16"# Clean up test data:
ssh n2 "rados -p cephtb4 cleanup"
Results
Write Performance:
Average Bandwidth: 1,294 MB/s
Peak Bandwidth: 2,076 MB/s
Average IOPS: 323
Average Latency: ~48ms
Read Performance:
Average Bandwidth: 1,762 MB/s
Peak Bandwidth: 2,448 MB/s
Average IOPS: 440
Average Latency: ~36ms
Step 25: Verify Configuration Database
Check that all optimizations are active in Proxmox GUI:
Navigate: Ceph → Configuration Database
Verify: All optimization settings visible and applied
Check: No configuration errors or warnings
Key optimizations to verify:
osd_memory_target: 8589934592 (8GB per OSD)
bluestore_cache_size_ssd: 4294967296 (4GB cache)
bluestore_compression_algorithm: lz4
cluster_network: 10.100.0.0/24 (TB4 mesh)
public_network: 10.11.12.0/24
Troubleshooting Common Issues
TB4 Mesh Issues
Problem: TB4 interfaces not coming up after reboot
Root Cause: Udev rules may not trigger on boot, scripts may be corrupted
Quick Fix: Manually bring up interfaces:
# Solution: Manually bring up interfaces and reapply SDN config:fornodein n2 n3 n4;do
ssh $node"ip link set en05 up mtu 65520"
ssh $node"ip link set en06 up mtu 65520"
ssh $node"ifreload -a"done
Permanent Fix: Check systemd service and scripts:
# Verify systemd service is enabled:fornodein n2 n3 n4;do
ssh $node"systemctl status thunderbolt-interfaces.service"done# Check if scripts are corrupted (should be ~13 lines, not 31073):fornodein n2 n3 n4;do
ssh $node"wc -l /usr/local/bin/pve-en*.sh"done# Check for shebang errors:fornodein n2 n3 n4;do
ssh $node"head -1 /usr/local/bin/*.sh | grep -E 'thunderbolt|pve-en'"done# If you see #\!/bin/bash (with backslash), fix it:fornodein n2 n3 n4;do
ssh $node"sed -i '1s/#\\\\!/#!/' /usr/local/bin/thunderbolt-startup.sh"
ssh $node"sed -i '1s/#\\\\!/#!/' /usr/local/bin/pve-en05.sh"
ssh $node"sed -i '1s/#\\\\!/#!/' /usr/local/bin/pve-en06.sh"done
Problem: Systemd service fails with "Exec format error"
Root Cause: Corrupted shebang line in scripts (#!/bin/bash instead of #!/bin/bash)
Diagnosis: Check systemctl status thunderbolt-interfaces for exec format errors
Solution: Fix shebang lines as shown above, then restart service
Problem: Mesh connectivity fails between some nodes
# Check interface status:fornodein n2 n3 n4;doecho"=== $node TB4 status ==="
ssh $node"ip addr show | grep -E '(en05|en06|10\.100\.0\.)'"done# Verify FRR routing service:fornodein n2 n3 n4;do
ssh $node"systemctl status frr"done
Ceph Issues
Problem: OSDs going down after creation
Root Cause: Usually network connectivity issues (TB4 mesh not working)
Solution: Fix TB4 mesh first, then restart OSD services:
I figured out the issue. The issue is with Ceph's config. I had the Ceph "Public" network set to my 1 Gb/s network and the Ceph "Cluster" network set to the Thunderbolt network. This was causing a massive bottleneck in the Ceph traffic as part of it was having to go through the slow 1 GB/s link. I do not use Ceph storage at all so once I set both the Ceph Public and Ceph Cluster network to use the Thunderbolt network, then everything exploded and is super fast. Now I get about 1.3 GB/s which is what I would expect. Hope this helps someone else!
i stood up a standard debian13 lxc, you could use helper scripts and it works fine, but give it a decent drive. i did 25g which was fine becuse i also turned it into my database server for later. I gave it .5/24 for testing grab fio apt-get install fio
Nice! See my previous post - I figured out why I was capped at ~175 MB/s. I had the Ceph Public and Ceph Cluster network set wrong. Once I changed the Ceph Public network over to the Thunderbolt network, I started getting 1.3 GB/s throughput on writes. Also now that you've given me some benchmark lines, I'll run some of those and see what results I get now that things are fixed. I'll get back with some results - tomorrow probably.
What Helper script did you use to test this? I'd like to try the same thing. I used a Debian 13 one but the write tests crash when using /tmp and its something to do with it being a ram /tmp and ChatGPT said I need to use a real disk location like /root or something.
Can you tell me which LXC you've got and which script it came from?
Oh i'm not using a helper script. I mean you can use theirs to install the lxc or vm for testing. use their debian 13 lxc would be the easiest. then make sure you install fio and you should be good?
Ah ok, you made it yourself. I’ll try that. For some reason, the writes to /tmp broke it and ended up crashing the host believe it or not. I’ll try a fresh LXC and try again using your exact commands with fio and get back to you.
Strange interface error which I have now... Yesterday I had only ipv4 ip adresses on the en05/06 and now only ipv6. What has now to be written in den interface config. In the first part of the config is described that I need to set ipv4 adresses on each en05/06 interface and on the second part nothing about that. Mine looks like this on the second node:
`auto lo
iface lo inet loopback
iface enp86s0 inet manual
auto vmbr0
iface vmbr0 inet static
address 192.168.1.92/24
gateway 192.168.1.1
bridge-ports enp86s0
bridge-stp off
bridge-fd 0
iface en05 inet manual #do not edit in GUI
iface en06 inet manual #do not edit in GUI
auto en05
iface en05 inet static
address 10.100.0.6/30
mtu 65520
auto en06
iface en06 inet static
address 10.100.0.9/30
mtu 65520
source /etc/network/interfaces.d/
root@pve2:~# ip a
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
inet 127.0.0.1/8 scope host lo
valid_lft forever preferred_lft forever
inet6 ::1/128 scope host noprefixroute
valid_lft forever preferred_lft forever
2: enp86s0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master vmbr0 state UP group default qlen 1000
link/ether 48:21:0b:56:08:69 brd ff:ff:ff:ff:ff:ff
altname enx48210b560869
3: vmbr0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000 link/ether 48:21:0b:56:08:69 brd ff:ff:ff:ff:ff:ff
inet 192.168.1.92/24 scope global vmbr0
valid_lft forever preferred_lft forever
inet6 fe80::4a21:bff:fe56:869/64 scope link proto kernel_ll
valid_lft forever preferred_lft forever
4: en05: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 65520 qdisc fq_codel state UP group default qlen 1000
link/ether 02:64:9e:4e:f6:62 brd ff:ff:ff:ff:ff:ff
inet6 fe80::64:9eff:fe4e:f662/64 scope link proto kernel_ll
valid_lft forever preferred_lft forever
5: en06: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 65520 qdisc fq_codel state UP group default qlen 1000
link/ether 02:28:b7:60:f6:af brd ff:ff:ff:ff:ff:ff
inet6 fe80::28:b7ff:fe60:f6af/64 scope link proto kernel_ll
valid_lft forever preferred_lft forever*`
Great article, and thanks for sharing.
Completely new to Proxmox and CephFS, so my apologies in advance for what may appear obvious to others but can I ask, regarding the TB4, point-to-point setup, what is the need for SDN setup when this is purely for the private Ceph cluster?
I have the IPv4 working via /31's with the following config:
pve01
iface en05 inet manual
#do not edit it GUI
iface en06 inet manual
#do not edit in GUI
# --- Thunderbolt mesh links (P2P /31s) ---
# en05 → pve02 (Link A, 10.100.0.0/31)
# pve01: 10.100.0.0/31 <-> pve02: 10.100.0.1/31
auto en05
iface en05 inet static
address 10.100.0.0/31
mtu 65520
# en06 → pve03 (Link C, 10.100.0.4/31)
# pve01: 10.100.0.4/31 <-> pve03: 10.100.0.5/31
auto en06
iface en06 inet static
address 10.100.0.4/31
mtu 65520
pve02
iface en05 inet manual
#do not edit it GUI
iface en06 inet manual
#do not edit in GUI
# --- Thunderbolt mesh links (P2P /31s) ---
# en05 → pve01 (Link A, 10.100.0.0/31)
# pve02: 10.100.0.1/31 <-> pve01: 10.100.0.0/31
auto en05
iface en05 inet static
address 10.100.0.1/31
mtu 65520
# en06 → pve03 (Link B, 10.100.0.2/31)
# pve02: 10.100.0.2/31 <-> pve03: 10.100.0.3/31
auto en06
iface en06 inet static
address 10.100.0.2/31
mtu 65520
pve03
iface en05 inet manual
#do not edit it GUI
iface en06 inet manual
#do not edit in GUI
# --- Thunderbolt mesh links (P2P /31s) ---
# en05 → pve02 (Link B, 10.100.0.2/31)
# pve03: 10.100.0.3/31 <-> pve02: 10.100.0.2/31
auto en05
iface en05 inet static
address 10.100.0.3/31
mtu 65520
# en06 → pve01 (Link C, 10.100.0.4/31)
# pve03: 10.100.0.5/31 <-> pve01: 10.100.0.4/31
auto en06
iface en06 inet static
address 10.100.0.5/31
mtu 65520
Technically speaking there is no need whatsoever. That way you have it working without SDN is the traditional way you'd need to do it. PVE9 introduced the ability to bring it "into the ui" . Sort of.. so I did CLI to get it working and have been slowly trying to answer questions about the UI? but I think some others have more updated versions with just UI maybe?
after reboot I always have to use the UI SDN to Apply the fabric again, but generally it’s working.
I went with the method to not use the /30 networks.
/etc/network/interfaces
auto lo
iface lo inet loopback
auto en05
iface en05 inet manual
mtu 65520
auto en06
iface en06 inet manual
mtu 65520
# ...
source /etc/network/interfaces.d/*
in MS-01 and proxmox 9.1.1 thunderbolt interfaces appears under network directly why i still need two en05 & en06 does it's required to link ip address?
in MS-01 and proxmox 9.1.1 thunderbolt interfaces appears under network directly why i still need two en05 & en06 does it's required to link ip address?
Yes, I’ve tried it, and the ports were detected during the initial Proxmox installation. If the cables are not connected at that stage, the interfaces will not appear later even if you plug them in afterward.
I figured out the issue. The issue is with Ceph's config. I had the Ceph "Public" network set to my 1 Gb/s network and the Ceph "Cluster" network set to the Thunderbolt network. This was causing a massive bottleneck in the Ceph traffic as part of it was having to go through the slow 1 GB/s link. I do not use Ceph storage at all so once I set both the Ceph Public and Ceph Cluster network to use the Thunderbolt network, then everything exploded and is super fast. Now I get about 1.3 GB/s which is what I would expect. Hope this helps someone else!