Guide on how to update the firmware and BIOS of a Lenovo ThinkSystem 430-x SAS/SATA 12Gb HBA.
- Broadcom Support Download Search
- STORCLI SAS3.5 P31
- STORCLI Documentation
- Lenovo Support Search
- Lenovo Storage Host Bus Adapter HBA Windows Firmware
- Download the latest STORCLI utility for LSI SAS3.5 Controllers per the reference above.
- Download the latest HBA (Windows) driver package per the reference above.
- Extract the packages to a folder on your local (Windows) machine.
- Copy the relevant files to a FAT32 formatted USB, for example:
storcli.efi16i_24_00_07_00.fwmpt35sas_x64_24_00_05_00.rommpt35sas_legacy_9_47_03_00.rom
- Boot to the USB via EFI shell.
- Identify the relevant (cX) HBA:
storcli.efi show all
- Confirm the relevant HBA:
storcli.efi /c0 show
- Backup STORCLI output to the USB:
storcli.efi /c0 show all > backup\output.txt
- Backup current controller bios, firmware etc. to the USB:
storcli.efi /c0 get bios file=backup\bios storcli.efi /c0 get firmware file=backup\firmware storcli.efi /c0 get mpb file=backup\mpb storcli.efi /c0 get fwbackup file=backup\fwbackup storcli.efi /c0 get nvdata file=backup\nvdata storcli.efi /c0 get flash file=backup\flash
- Update the firmware:
storcli.efi /c0 download file=16i_24_00_07_00.fw
- Update the EFI BIOS:
storcli.efi /c0 download efibios file=mpt35sas_x64_24_00_05_00.rom
- Update the BIOS:
storcli.efi /c0 download bios file=mpt35sas_legacy_9_47_03_00.rom
- Check HBA versions have updated:
storcli.efi /c0 show
- Power cycle the machine.
Yeah nobody else knows what is special about that cable, too. From images we can infer that it has no active components but they way it connects to the controller must be special.
The people at servthehome did it with u.2 to m.2 adapters. So for me, that confirms the cable is the critical part.
If you look at it it seems there are only genuine cables which connect 2x SAS8643 to 2x U.2. I would speculate that this is for some reason...
https://www.genuinemodules.de/05-50065-00