| # Helpful information: | |
| # https://github.com/Excodibur/ioBroker.schwoerer-ventcube/blob/master/src/lib/schwoerer/parameters.ts | |
| # https://github.com/fgoettel/wgt/blob/main/wgt/lueftungsanlage.py | |
| # https://knx-user-forum.de/forum/öffentlicher-bereich/knx-eib-forum/diy-do-it-yourself/1822296-modbus-schwörer-heizung?p=1906252#post1906252 | |
| ################## | |
| # MODBUS SENSORS # | |
| ################## | |
| modbus: | |
| - name: BIC_VentCube | |
| delay: 2 | |
| timeout: 3 | |
| type: tcp | |
| host: !secret wgt_ip | |
| port: 502 | |
| sensors: | |
| - name: VentCube Betriebsart | |
| slave: 1 | |
| unique_id: ventcube_betriebsart | |
| address: 100 | |
| # Translated with template sensor | |
| # Translated with input_select Automation | |
| - name: VentCube Manuelle Luftstufe | |
| slave: 1 | |
| unique_id: ventcube_manuelle_luftstufe | |
| address: 101 | |
| # Translated with input_select Automation | |
| - name: VentCube Aktuelle Luftstufe | |
| slave: 1 | |
| unique_id: ventcube_aktuelle_luftstufe | |
| address: 102 | |
| - name: VentCube Status Stoßlüftung | |
| slave: 1 | |
| unique_id: ventcube_status_stosslueftung | |
| address: 111 | |
| # Translated with template sensor | |
| - name: VentCube Restlaufzeit Stoßlüftung | |
| slave: 1 | |
| unique_id: ventcube_restlaufzeit_stosslueftung | |
| address: 112 | |
| unit_of_measurement: min | |
| device_class: duration | |
| min_value: 0 | |
| max_value: 60 | |
| - name: VentCube Status Wärmepumpe | |
| slave: 1 | |
| unique_id: ventcube_status_waermepumpe | |
| address: 114 | |
| # Translated with template sensor | |
| - name: VentCube Status Nachheizregister | |
| slave: 1 | |
| unique_id: ventcube_status_nachheizregister | |
| address: 116 | |
| # Translated with template sensor | |
| - name: VentCube Status Gebläse Zuluft | |
| slave: 1 | |
| unique_id: ventcube_status_geblaese_zuluft | |
| address: 117 | |
| # Translated with template sensor | |
| - name: VentCube Status Gebläse Abluft | |
| slave: 1 | |
| unique_id: ventcube_status_geblaese_abluft | |
| address: 118 | |
| # Translated with template sensor | |
| - name: VentCube Bypass Zustand | |
| slave: 1 | |
| unique_id: ventcube_bypass_zustand | |
| address: 123 | |
| # Translated with template sensor | |
| - name: VentCube Zustand Außenklappe | |
| slave: 1 | |
| unique_id: ventcube_zustand_aussenklappe | |
| address: 131 | |
| # Translated with template sensor | |
| - name: VentCube Status Vorheizregister | |
| slave: 1 | |
| unique_id: ventcube_status_vorheizregister | |
| address: 133 | |
| # Translated with template sensor | |
| - name: VentCube aktuelle Luftleistung Zuluft | |
| slave: 1 | |
| unique_id: ventcube_aktuelle_luftleistung_zuluft | |
| address: 142 | |
| state_class: measurement | |
| unit_of_measurement: "%" | |
| min_value: 0 | |
| max_value: 100 | |
| scale: 1 | |
| precision: 0 | |
| - name: VentCube aktuelle Luftleistung Abluft | |
| unique_id: ventcube_aktuelle_luftleistung_abluft | |
| slave: 1 | |
| address: 143 | |
| state_class: measurement | |
| unit_of_measurement: "%" | |
| min_value: 0 | |
| max_value: 100 | |
| scale: 1 | |
| precision: 0 | |
| - name: VentCube aktuelle Drehzahl Zuluft | |
| unique_id: ventcube_aktuelle_drehzahl_zuluft | |
| slave: 1 | |
| address: 144 | |
| state_class: measurement | |
| unit_of_measurement: "rpm" | |
| min_value: 0 | |
| max_value: 10000 | |
| precision: 0 | |
| - name: VentCube aktuelle Drehzahl Abluft | |
| unique_id: ventcube_aktuelle_drehzahl_abluft | |
| slave: 1 | |
| address: 145 | |
| state_class: measurement | |
| unit_of_measurement: "rpm" | |
| min_value: 0 | |
| max_value: 10000 | |
| precision: 0 | |
| - name: VentCube T2 Temperatur nach Vorheizregister | |
| slave: 1 | |
| unique_id: ventcube_t2_temperatur_nach_vorheizregister | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 201 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T3 Temperatur vor Nacherwärmung | |
| slave: 1 | |
| unique_id: ventcube_t3_temperatur_vor_nacherwaermung | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 202 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T4 Temperatur nach Nacherwärmung | |
| slave: 1 | |
| unique_id: ventcube_t4_temperatur_nach_nacherwaermung | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 203 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T5 Temperatur Abluft | |
| slave: 1 | |
| unique_id: ventcube_t5_temperatur_abluft | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 204 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T6 Temperatur im Wärmetauscher | |
| slave: 1 | |
| unique_id: ventcube_t6_temperatur_im_waermetauscher | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 205 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T10 Temperatur Außen | |
| slave: 1 | |
| unique_id: ventcube_t10_temperatur_aussen | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 209 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube Heiz- Kühlfunktion | |
| slave: 1 | |
| unique_id: ventcube_heiz_kuehlfunktion | |
| address: 230 | |
| # Translated with template sensor | |
| # Translated with input_select Automation | |
| - name: VentCube Wärmepumpe Heizen | |
| slave: 1 | |
| unique_id: ventcube_wp_heizen | |
| address: 231 | |
| - name: VentCube Wärmepumpe Kühlen | |
| slave: 1 | |
| unique_id: ventcube_wp_kuehlen | |
| address: 232 | |
| - name: VentCube Druckwächter aktiv | |
| slave: 1 | |
| unique_id: ventcube_druckwachter_aktiv | |
| address: 242 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube EVU Sperre aktiv | |
| slave: 1 | |
| unique_id: ventcube_evu_sperre_aktiv | |
| address: 243 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Wartungstür offen | |
| slave: 1 | |
| unique_id: ventcube_wartungstur_offen | |
| address: 244 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Gerätefilter verschmutzt | |
| slave: 1 | |
| unique_id: ventcube_geratefilter_verschmutzt | |
| address: 245 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Vorgelagerter Filter verschmutzt | |
| slave: 1 | |
| unique_id: ventcube_vorgelagerter_filter_verschmutzt | |
| address: 246 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Zuluft zu kalt | |
| slave: 1 | |
| unique_id: ventcube_zuluft_zu_kalt | |
| address: 254 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Restlaufzeit Gerätefilter | |
| slave: 1 | |
| unique_id: ventcube_restlaufzeit_geratefilter | |
| address: 265 | |
| unit_of_measurement: d | |
| min_value: 0 | |
| max_value: 255 | |
| device_class: duration | |
| - name: VentCube Temperatur Wohnzimmer IST | |
| slave: 1 | |
| unique_id: ventcube_temperatur_wohnzimmer_ist | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 360 | |
| scale: 0.1 | |
| precision: 1 | |
| min_value: 0 | |
| max_value: 100 | |
| switches: | |
| - name: VentCube Freigabe WP auf Heizen | |
| slave: 1 | |
| address: 231 | |
| command_on: 0x1 # Freigabe | |
| command_off: 0x0 # Gesperrt | |
| write_type: holdings | |
| verify: | |
| input_type: holding | |
| state_on: 0x1 | |
| state_off: 0x0 | |
| delay: 5 | |
| unique_id: ventcube_set_waermepumpe_heizen | |
| - name: VentCube Freigabe WP auf Kühlen | |
| slave: 1 | |
| address: 232 | |
| command_on: 0x1 # Freigabe | |
| command_off: 0x0 # Gesperrt | |
| write_type: holdings | |
| verify: | |
| input_type: holding | |
| state_on: 0x1 | |
| state_off: 0x0 | |
| delay: 5 | |
| unique_id: ventcube_set_waermepumpe_kuehlen | |
| climates: | |
| - name: "VentCube Soll-Temperatur" | |
| unique_id: ventcube_soll_temperatur | |
| slave: 1 | |
| address: 400 | |
| max_temp: 30 | |
| min_temp: 10 | |
| offset: 0 | |
| precision: 0 | |
| scale: 0.1 | |
| target_temp_register: 400 | |
| target_temp_write_registers: true | |
| temp_step: 1 | |
| temperature_unit: °C | |
| - name: "VentCube Basis-Temperatur" | |
| unique_id: ventcube_basis_temperatur | |
| slave: 1 | |
| address: 420 | |
| max_temp: 30 | |
| min_temp: 18 | |
| offset: 0 | |
| precision: 0 | |
| scale: 0.1 | |
| target_temp_register: 420 | |
| target_temp_write_registers: true | |
| temp_step: 1 | |
| temperature_unit: °C | |
| ##################################################### | |
| # Select Options which require separate Automations # | |
| ##################################################### | |
| input_select: | |
| ventcube_manuelle_luftstufe: | |
| name: VentCube Manuelle Luftstufe | |
| options: | |
| - "0 - Aus" | |
| - "1 - Stufe 1" | |
| - "2 - Stufe 2" | |
| - "3 - Stufe 3" | |
| - "4 - Stufe 4" | |
| - "5 - Automatik" | |
| - "6 - Linearbetrieb" | |
| icon: mdi:fan | |
| ventcube_betriebsart: | |
| name: VentCube Betriebsart | |
| options: | |
| - "0 - Aus" | |
| - "1 - Handbetrieb" | |
| - "2 - Winterbetrieb" | |
| - "3 - Sommerbetrieb" | |
| - "4 - Sommer Abluft" | |
| icon: mdi:fan | |
| ventcube_heiz_kuehlfunktion: | |
| name: VentCube Heiz- Kühlfunktion | |
| options: | |
| - "0 - Aus" | |
| - "1 - Heizen" | |
| - "2 - Kühlen" | |
| - "3 - Auto T-Außen" | |
| - "4 - Auto Digitaler Eingang" | |
| icon: mdi:fan | |
| #################### | |
| # TEMPLATE SENSORS # | |
| #################### | |
| sensor: | |
| - platform: template | |
| sensors: | |
| ventcube_betriebsart_text: | |
| unique_id: ventcube_betriebsart_text | |
| friendly_name: "VentCube Betriebsart" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'Handbetrieb', | |
| '2': 'Winterbetrieb', | |
| '3': 'Sommerbetrieb', | |
| '4': 'Sommer Abluft'} %} | |
| {% set state = states.sensor.ventcube_betriebsart.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_bypass_zustand_text: | |
| unique_id: ventcube_bypass_zustand_text | |
| friendly_name: "VentCube Zustand Bypass" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Geschlossen', | |
| '1': 'Offen (Kühlen)', | |
| '2': 'Offen (Heizen)'} %} | |
| {% set state = states.sensor.ventcube_bypass_zustand.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_zustand_aussenklappe_text: | |
| unique_id: ventcube_zustand_aussenklappe_text | |
| friendly_name: "VentCube Zustand Außenklappe" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Geschlossen', | |
| '1': 'Offen'} %} | |
| {% set state = states.sensor.ventcube_zustand_aussenklappe.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_waermepumpe_text: | |
| unique_id: ventcube_status_waermepumpe_text | |
| friendly_name: "VentCube Status Wärmepumpe" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '5': 'WP Heizen', | |
| '49': 'WP Kühlen'} %} | |
| {% set state = states.sensor.ventcube_status_waermepumpe.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_heiz_kuehlfunktion_text: | |
| unique_id: ventcube_heiz_kuehlfunktion_text | |
| friendly_name: "VentCube Status Heiz- Kühlfunktion" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'Heizen', | |
| '2': 'Kühlen', | |
| '3': 'Auto T-Außen', | |
| '4': 'Auto Digitaler Eingang'} %} | |
| {% set state = states.sensor.ventcube_heiz_kuehlfunktion.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_nachheizregister_text: | |
| unique_id: ventcube_status_nachheizregister_text | |
| friendly_name: "VentCube Status Nachheizregister" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Inaktiv', | |
| '1': 'Aktiv'} %} | |
| {% set state = states.sensor.ventcube_status_nachheizregister.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_vorheizregister_text: | |
| unique_id: ventcube_status_vorheizregister_text | |
| friendly_name: "VentCube Status Vorheizregister" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'VHR1 Aktiv', | |
| '2': 'VHR2 Aktiv', | |
| '3': 'VHR1+2 Aktiv'} %} | |
| {% set state = states.sensor.ventcube_status_vorheizregister.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_stosslueftung_text: | |
| unique_id: ventcube_status_stosslueftung_text | |
| friendly_name: "VentCube Status Stoßlüftung" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Inaktiv', | |
| '1': 'Aktiv'} %} | |
| {% set state = states.sensor.ventcube_status_stosslueftung.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_geblaese_zuluft_text: | |
| unique_id: ventcube_status_geblaese_zuluft_text | |
| friendly_name: "VentCube Status Gebläse Zuluft" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Deaktiviert', | |
| '1': 'Anlaufphase', | |
| '2': 'Aktiv', | |
| '5': 'Standby', | |
| '6': 'Fehler'} %} | |
| {% set state = states.sensor.ventcube_status_geblaese_zuluft.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_geblaese_abluft_text: | |
| unique_id: ventcube_status_geblaese_abluft_text | |
| friendly_name: "VentCube Status Gebläse Abluft" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Deaktiviert', | |
| '1': 'Anlaufphase', | |
| '2': 'Aktiv', | |
| '5': 'Standby', | |
| '6': 'Fehler'} %} | |
| {% set state = states.sensor.ventcube_status_geblaese_abluft.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| template: | |
| - binary_sensor: | |
| - name: "VentCube Meldung Druckwächter Aktiv" | |
| unique_id: ventcube_meldung_druckwachter_aktiv | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_druckwachter_aktiv.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung EVU Sperre aktiv" | |
| unique_id: ventcube_meldung_evu_sperre_aktiv | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_evu_sperre_aktiv.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Wartungstür offen" | |
| unique_id: ventcube_meldung_wartungstur_offen | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_wartungstur_offen.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Gerätefilter verschmutzt" | |
| unique_id: ventcube_meldung_geratefilter_verschmutzt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_geratefilter_verschmutzt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Vorgelagerter Filter verschmutzt" | |
| unique_id: ventcube_meldung_vorgelagerter_filter_verschmutzt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'on', | |
| '1': 'off'} %} | |
| {% set state = states.sensor.ventcube_vorgelagerter_filter_verschmutzt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Zuluft Zu Kalt" | |
| unique_id: ventcube_meldung_zuluft_zu_kalt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_zuluft_zu_kalt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
Hi @Markus1010RT, danke dir.
Nur um sicher zu gehen: Ich gehe davon aus, du hast deine VentCube nach Aktivieren von Modbus via TCP/IP neugestartet? Hier im Thread steht was von Sicherung raus/rein, aber es geht auch per Schwörer-Bedienteil: Solange man sich noch im Service-Modus befindet -> Einstellungen -> Grundeinstellungen -> 11. Datensatz verwalten -> 6. Geräte Neustart Leistungsteil; ich habe sicherheitshalber auch "7. Geräte Neustart BT-S2" ausgeführt.
Ich konnte mich direkt nach Aktivieren von Modbus TCP/IP auf einem Unix-Betriebssystem via netcat davon überzeugen, dass der Port nun offen ist (via nc -vz <ip> 502, also bspw. nc -vz 192.168.1.123 502). Eben nochmal getestet, erhalte ich mittlerweile nur noch einen Connection Timeout, obwohl sich HA weiterhin erfolgreich verbinden kann. Wenn du per netcat eine erfolgreiche Verbindung aufbauen kannst, prima! Beim Ergebnis "Connection Timeout" stehen die Chancen jedoch 50:50.
Du kannst aber auch mit Modbus-Tools prüfen, ob du einzelne Adressen abrufen kannst (oder, für Fortgeschrittene, wahlweise direkt per netcat mit Modbus kommunizieren). Dann hättest du wenigstens Gewissheit, ob es an HA oder der Lüftungsanlage liegt. Ich hatte mal Tools recherchiert, aber noch keines ausgetestet.
Ansonsten, was sagt Home Assistant zur Verbindung? Gibt es entsprechende Einträge im Log?
Andernfalls ggf. das Loglevel temporär hochdrehen, siehe https://www.home-assistant.io/integrations/modbus/ Kapitel "Opening an issue", und danach wahlweise HA neustarten oder die Modbus-YAML-Konfiguration neu laden.
Habe deine .yml und .jinja erstellt und die IP angepasst. Die Sensoren funktionieren als Zahl, aber leider nicht als Text:
Wenn die Zustände ausgelesen werden können wie man sieht, wieso werden die Text Sensoren nicht angezeigt?
Zudem kann ich bei den neuen Auswahlfeldern leider nichts auswählen:
Gruß Tobias
Hi @tobse91,
nur um sicher zu gehen: ich gehe davon aus, dass die Macros unter /custom_templates/ abgelegt wurden und Home Assistant danach neugestartet wurde? So sieht die Struktur bei mir aus:
Du kannst die Funktionstüchtigkeit der Macros testen, indem du bspw. folgenden Schnipsel unter Entwicklerwerkzeuge > Template einfügst:
{% from 'schwoererhaus_ventcube_fresh.jinja' import ventcube_operation_mode as func %}
{{ func('values') }}
Erscheint dort folgende Ausgabe, können die Macros als Fehlerursache ausgeschlossen werden:

Da dein Dropdown leer ist, das genannte Macro aber die Listeneinträge für das betroffene Feld erzeugen soll, vermute ich die Fehlerursache an dieser Stelle.
Der Modbus-Sensor für die Betriebsart hat tatsächlich die ID "sensor.ventcube_operation_mode", wie vom Template-Select so erwartet?
Viele Grüße
Benjamin
Hi,
also ich habe es heute mal mit dem neu laden des modbus versucht, aber nach wie vor sieht es eher schlecht aus.
Was mich auch ein wenig wundert ist, dass ich alles doppelt und dreifach habe :D ich vermute aber, das kommt von meinen diversen versuchen des neu hinzufuegens der modbus integration.
Ich hab die Einstellungen am Bedienteil auch nochmals geprüft. die ip stimmt und modbus tcp ist auch aktviert